Request Information Download PDF Configure Output Connector
GT-46240-24VV-x.x-T3A GT-46240-24VV-x.x-T3A
Information
Model NumberGT-46240-24VV-x.x-T3A
DescriptionGT-46240-24VV-x.x-T3A, ITE Power Supply, Desktop/External, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, IEC 60320/C6 AC Inlet Connector, Class I, Earth Ground ( aka "Mickey Mouse"), Output Rating: 24 Watts, 12-24V in 0.1V increments, Approvals: cUL S-Mark 230V CoC Tier 2 CE China RoHS Class I IP42 Level VI LPS PSE RoHS 2 Ukraine VCCI WEEE RCM CCC
Agency Documentshttp://www.globtek.info/certs/GT-46240-24VV-x.x-TZ/
CE EC-Declaration for MedicalContact GlobTek for more information
CE EC-Declaration for Industrial/Commercial/ITEhttp://globtek.force.com/models/ec_declaration?id=a0Oa000000MnJ4pEAF
RoHS/RoHS3 Declarationhttp://www.globtek.com/pdf/rohs_cert/a0Oa000000MnJ4pEAF
REACH Declarationhttp://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttp://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeDesktop/External
TechnologyRegulated Switchmode AC-DC Power Supply AC Adaptor
CategoryITE Power Supply
Input Voltage100-240V~, 50-60 Hz
I/P Amps (A)0.6 A
Wattage (W)24
Vout Range (V)12-24
EfficiencyVI
Ingress ProtectionIndoor Use
Size (mm)80.6*50.0*31.0
EnclosureUser-added image
 
Rating Table
Model Number VoltageAmps (A)Watts (W) RFQ
SpecificationsA) ELECTRICAL SPECIFICATIONS:
01. Input Voltage: Specified 90-264 Vac, Nameplate rated: 100-240Vac
02. Input Frequency: Specified 47-63 Hz, Nameplate rated 50-60Hz
03. Inrush Current: 50A Max. at 115VAC cold start, 100A Max. at 230VAC cold start
04. Average Efficiency: 82.44% Min (CEC & DOE LEVEL VI Compliant), 82.97% Min (ErP Tier2 Compliant)
05. Input power(no load): <0.1W (CEC & DOE LEVEL VI Compliant), <0.075W (ErP Tier2 Compliant)
07. Output Voltage toterance: ±5%
08.Load regulation: ±5%
09. Output Voltage: Tolerance ± 5%
10. Turn On Delay: 3000 mS MAX at 115 VAC Full Load
11. Hold Up Time: 10 mS Min at 100 VAC Full Load
12. Ripple Voltage: 150mV (p-p): Input :(100V-240VAC ), Output:full load
Measuring is done by 20MHz bandwidth oscilloscope and terminated each output with a 10uF aluminum electrolytic capacitor and 0.1uF ceramic capacitor.

B) PROTECTION
01. Over voltage protection: protection zener
02. Short circuit protection: Output shut down and auto- recover
03.Over Load Protection: Output shut down and auto restart

C) SAFETY
01. HI-POT : Input to output : 1500VAC or 2121VDC 10mA 1 minute
02. Earth Leakage Current: <3.5 mA at 240Vac input voltage
03. Insulation resistance: Input to output: 500vdc to test the input to output resistance not be less 100M ohm
04. Earth continuity test:<0.1 Ohm or < 0.2 Ohm when with a non-detachable Power Supply cord, Class I Only

D) OTHER:
01. MTBF: 200,000 Hours @ 25°C ambient temperature
02. Operating Temperature: 0°C to 40°C ambient temperature
03. Humidity Operating : 20% to 80%. 0% to 90% relative humidity
04. Storage Temperature: -10°C to 70°C
Humidity Storage: 10% to 90%
05. RoHS 2: Complies with EU 2011/65/EU andChina SJ/T 11364-2014

E) ENCLOSURE
01. Housing: High impact plastic, 94V0 polycarbonate, non-vented
02. Size: 80.6*50.0*31.0 +/-1.0 mm
03. Markings: Label and/or Pad Printed and/or Molded in the case
Derating CurveUser-added image
 
Qty (ea.)/Carton80
Individual Box/Gift Box Size (mm)Egg Crate
Individual Box/Gift Box ColorWhite
Master Carton Size (mm)510 x 350 x 272
Gross Weight (kg)8.4
Label Width (mm)59.6
Label Height (mm)39.6
Input Configuration
DescriptionIEC 60320/C6 AC Inlet Connector, Class I, Earth Ground ( aka "Mickey Mouse")User-added image

Mates with IEC 60320/C5 Plug

 
 Standard International IEC 320/C Cordsets

Below are standard cordsets which are "not included" (unless stated above); these can be purchased separately or package with the power supply. Contact your Sales Engineer if the style required is not shown below. Many more available in different lengths, colors or cable material.

3021066F712(R)

N. American

NEMA 5-15P

IEC 320/C5

1880

6

1191068F0712(R)

N. American

NEMA 5-15P Hospital

IEC 320/C5

2459

8

2064262M0712(R)

Australian

AS3112 / 3 PRONG

IEC 320/C5

2050

7

204B4262M0712(R)

Brazil

BRAZILIAN; WS-002

IEC 320/C5

2050

7

6023592M5712(R)

China

CCC GR2099

IEC 320/C5

2500

8

23144262M0712(R)

Europe

CEE 7/7

IEC 320/C5

2050

7

2084262M0712(R)

India/S.Africa

India/S.Africa

IEC 320/C5

2050

7

23024262M0712(R)

Italy

CEI 23-16/VII

IEC 320/C5

2050

7

3003316F0712(R)

Japan

JIS 8303 / 3 PINS

IEC 320/C5

1830

6

23214262M0712(R)

Switzerland

SEV 1011 ( EL 203)

IEC 320/C5

2050

7

6104262M0712(R)

UK

BS1363

IEC 320/C5

2050

7

Output Configuration
Common output connector options:
Click to add to your request.






L Type (Coaxial 5.5x2.5mm plug) C Type (Coaxial 5.5x2.1mm plug) K Type (Coaxial 3.5x1.3mm plug) LL Type (5.5x2.5mm Locking 760k type) CL Type (5.5x2.1mm Locking S761k type) Magnetic Connector





YL3 Type (KPPX-3P) YL4 Type (KPPX-4P) EJ1/2/3/4/5 (EIAJ RC-5320A type connectors) MSB Type (Micro USB) Inquire for custom design

For a comprehensive list of options, click here

Contact GlobTek for your specific requirements or custom solutions.

Approvals
LogoDescription
No Logo ApplicableEU 230V CoC Tier 2, 278/2009, Mar 2014
User-added imageCCC to GB4943.1-2011 GB9254-2008 GB17625.1-2012
User-added image  CE Mark: tested to comply with EN55022:2010 Class B, EN61000-3-2, EN61000-3-3 including EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6N EN61000-4-11; EMI: Complies with EN55011 CLASS B and FCC Part 15B - On label or Molded in case
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
User-added image
Class I Earth Ground
User-added imageUL 60950-1, 2nd Edition, 2014-10-14 (Information Technology Equipment - Safety - Part 1: eneral Requirements) CAN/CSA C22.2 No. 60950-1-07, 2nd Edition, 2014-10 (Information Technology Equipment - Safety - Part 1: General Requirements)
User-added imageIndoor Use Only - Mark is on the label or Molded in the case
IP42Ingress Protection: IP42 to IEC60529:2001 Protection against granular foreign bodies - Protected against direct sprays up to 15o from the vertical Optional
 User-added image
 
Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
LPSLimited Power Source
User-added imageJAPAN TUV Rheinland-PSE GlobTek Inc to J60950-1(H26) , J55022(H22),J3000(H25).Please follow the procedure listed in the following link for proper import to Japan: http://en.globtek.com/importing-to-japan.php.
User-added image
 
RCM certificate SAA-160907-EA; Australia and New Zealand Regulatory Compliance, Mark (http://rcm.standards.org.au/rcmfaq/rcmfaq.htm
RoHSSpecifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
User-added imageS-Mark Certificate EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 +A2:2013 (http://www.intertek.com/marks/s/)
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case